| |
Aircraft corrosion is a problem you can't afford
to ignore!
ACF-50 was developed 15 years ago and has amassed a record of performance
unique in the aerospace industry. Here are some of its unique properties:
- ACF-50 is an excellent penetrant.
- ACF-50 provides excellent low-shear lubrication
to moving parts and cables.
- ACF-50 kills any corrosion currently in progress
with just one application.
- Removal of the corrosion by-product is not necessary.
- ACF-50 is good for rubber, preventing it from cracking
or drying out.
- In most applications, ACF-50's unique properties
will last for 24 months before it is consumed and needs to be re-applied.
- The ultra-thin-film does not attract and hold salt
crystals and dirt particles.
- The ultra-thin film does not "dry". It
stays a flexible liquid and therefore seals the surface better as the
surface expands and contracts.
- ACF-50 will not displace or melt any grease which
is already in place. It will mix with it and make it more efficient.
- ACF-50 will not support combustion.
- ACF-50 has a very low percentage of Volatile Organic
Compounds (less than 17%).
- ACF-50 is non-carcinogenic and virtually non-toxic.
Incidentally, full toxicality testing has been done to support this
claim.
- ACF-50 can be easily removed with MEK or soap and
water.
- ACF-50 will not harm any plastics or painted surfaces.
- ACF-50 can be safely applied to electronics such
as radios, timers, test equipment, antenna connections, computers, etc.
However, we recommend you avoid using it on LED's, LCD's and soft membrane
switches.
- ACF-50 can be safely applied to electrical components
such as alternators, starters, magnetos, generators, distributors, carburators,
wiring, switches, rheostats, compressors, battery terminals, light bulb
sockets, electrical connectors, circuit breakers, ignition systems,
wire harnesses, etc.
- ACF-50 meets the performance requirements of Mil-C-
81309E Type II and Type III, as well as BMS 3-23E, CSD#1, DMS 2150,
and TN A 007.10138. It is also listed on the United States Coast Guard
Authorized Chemical List for the HC-130 platform.
- ACF-50 holds written OEM approvals from the following
manufacturers: Bombardier Regional Aircraft, Douglas/Boeing Helicopter,
ATR Regional Transport, Bell Helicopter Textron, The New Piper Aircraft,
Gulfstream Aerospace, Robinson Helicopter, McDonnell Douglas, Enstrom
Helicopter, Schweitzer Aircraft, British Aerospace, Concorde Battery,
Raytheon Aircraft, Sikorsky Aircraft, MD Helicopters, Cessna Aircraft,
Pilatus Aircraft, Beech Aircraft, Van's Aircraft, Extra Aircraft, Hiller
Aircraft, Air Tractor, Lake Aircraft, Rolls-Royce, Britten-Norman Aircraft,
Learjet, and Canadair.

ACF-50 actually costs less than other products since:
- It lasts for 24 months.
- Application is fast and easy with virtually no cleanup.
It doesn't leave a sticky, waxy mess during application, thereby reducing
cleanup time.
- It has excellent coverage-3,000 sf when used with
our fogging system.
- Corrosion-related replacement and repair costs are
cut substantially.
- Inspections can be performed without labor-intensive
removal procedures.
- Corrosion prevention and control become more predictable,
as an application can be done during regularly scheduled annual maintenance
without the need for extended down time.

WHAT IS
CORROSION?
|
1. THE CORROSION PROCESS:
When moisture is present for prolonged periods of time, corrosion
"cells" are formed. These cells act as miniature batteries,
feeding the transfer of electrons as long as any oxygen-providing
moisture is present.
|
 |
2. WAXES RETAIN WATER:
Most corrosion inhibitors contain sealants such as wax, tar, asphalt,
teflon or silicone that lay on top of the corrosion cell. Because
of their thick composition, they cannot remove the electrolyte and
may actually seal it in, thereby encouraging corrosion.
|
 |
3. THE ACF 50 IS FOGGED INTO THE AIRFRAME:
The recommended way to apply ACF-50 is to use a specially-designed
high pressure pump system to convert it into a dense fog.
|
 |
4. ACF 50 PENETRATES THE CORROSION
BYPRODUCT:
ACF-50's ultra-thin formula easily penetrates the entire corrosion
cell.
|
 |
5. ACF 50 EJECTS THE ELECTROLYTE:
The encapsulated and emulsified electrolyte is ejected from the
corrosion cell and replaced with ACF 50.
|
 |
6. NO ELECTROLYTE-NO CORROSION:
The ACF50 acts as an insulator, terminating the electrolytic process
for 24 months!
|
 |

Give us a call for cost for treatment of your aircraft.
For free advice contact Stuart J. Vincent.
Tel: +44 (0)1452 855501
Email: mail@rgv.co.uk
|
|